|
|
TEACHER REFERENCE PAGES |
GC Instructions |
INTRODUCTION
Esters are important industrial and biological compounds.
Fats (1) are esters of three long-chain carboxylic acids with glycerol,
a triol. The pleasant odors from fruits are complex mixtures consisting
primarily of volatile esters. The odor of isopentyl acetate (2) is
that of bananas or pears, butyl butanoate (3) resembles pineapples, and
propyl 2-methylpropanoate (4) is like that of rum. Polyesters constitute
an important part of the synthetic polymer field. Polyesters such
as Dacron (5), Terylene, and Mylar are marketed and widely used to make
clothing fiber, tire cord, or plastic film.
In this experiment, students will synthesize isopentyl
acetate (banana oil) from acetic acid and isopentyl alcohol. After
purification, banana oil will be identified not only by its odor but also
characterized by using a modern technique, gas chromatography.
![]() |
One major technique that is used to study organic molecules is gas chromatography. Gas chromatography (GC) is the separation of compounds in the gas phase, depending on their relative ability to adsorb onto the column packing and their volatility into the gas phase at the temperature used. The gas chromatograph is a simple, sensitive instrument which can be used to separate and identify about 60% of all known organic compounds.
The compounds to be separated are injected into a gas stream which passes through a column at a preset speed. Under a constant set of conditions in terms of temperature, gas flow rate, and column packing and size, repeated injections of a compound elute from (come out of) the column at a nearly constant time from injection. Different compounds elute at different times. One factor which affects elution time is the molecular weight of the compound; heavier compounds move more slowly through the column. Elution time is also affected by polarity and other factors. The column is first injected with known compounds called standards, and their retention times are determined. Then, unknown mixtures of compounds can be injected, and if the known compounds are in the mixture, their peaks can be recognized by their characteristic retention times.
A gas chromatograph detects the presence of a compound in its eluate (exiting stream) by means of some property of the compound. One common method used by GC detectors is to compare the conductivity of a heated filament which is placed within a stream of pure reference gas (helium in our lab) to a heated filament placed in a stream of gas containing our sample molecules. When molecules from our sample pass the detector filament, the changes in conductivity caused by temperature changes are converted into electrical signals which appear as peaks on a computer data screen. Peaks seen in the eluate are plotted on a chart, and the integrated peak area is proportional to the concentration of the compound. Many GCs report the integral area of each of the peaks, following the plotted graph of the peaks. An approximate proportionality between peak height and concentration can also be seen (see sample printouts).
Directions on the use of the HP 5890 Gas Chromatograph.
EQUIPMENT
10 Stirring Hotplates
10 Microkits
Micropipets
2 Gas Chromatographs
2 Analytical Balances
SUPPLIES
| 10 Ring Stands
10 3-finger Clamps 4 DI Water Washbottles 4 Acetone Washbottles 20 Tygon tubing 20 Sample Vials |
10 Heating blocks & collars
10 Metal Thermometers 1 Box Gloves Cotton 20 Pasteur pipets |
| Glacial Acetic Acid
95% H2SO4 Isopentyl Alcohol CaCl2 |
5% NaHCO3
Anhydrous MgSO4 Acetone GC Standards |
Students should understand the following terms before running this lab: Adsorption, Absorbtion, Distillate, Eluate, Elution time, Polarity, Reflux band, Volatility.
Start heating the heating blocks as early as possible; it takes time for the temperature to rise and stabilize.
Review the assembly of the microscale kit with students. You may copy the handout for the students if you wish, or just instruct them in the assembly. The parts of this kit are expensive and breakable. Please urge caution. Also review use of the automatic pipettors and preset them to the required amounts. Caution students regarding use of the magnetic stirrers, and the process of cooling the vial in step 7. If time is a problem, students may stop after step 7, or after step 16 and resume at a later time. In step 15, the amount of anhydrous MgSO4 should be sufficient to dry the product. The purification step is not essential to the lab. You may have the students do it if you choose.
The distillate will be tested by means of gas chromatography. Review the instructions for operating the gas chromatograph. First, as a teacher demonstration, inject about one microliter of the isopentyl alcohol standard into the gas chromatograph. Observe the time that it takes for the peak to appear. This should be done on both gas chromatographs. Then, a standard containing a mixture of water, acetone, acetic acid, isopentyl alcohol, and isopentyl acetate will be injected. Observe the time it takes for each of the five peaks to appear.
Have the students record the retention times and names of the standards onto their data tables. Notice that the retention times will vary slightly with each machine due to the condition of its columm and rate of gas flow. Remind students that they must run their samples through the same machine for which they are recording standard retention times. For convenience, the machines will be labeled A and B (or C).
Next, have students inject about one microliter of their distillate in turn into the gas chromatograph. This will take 8-10 minutes per group. Have students record the machine code number (A, B or C), and then identify the peaks by name and the percentage yield of each compound in their sample (see page 7). This information will be written on their computer printout first, and then transfered to their data table. The students will need to refer to the data from the standards to identify the components of their sample. Doing examples on paper prior to the lab day will greatly increase the students' understanding of these procedures. They should see three peaks, one for water, one for isopentyl alcohol, and one for isopentyl acetate. Any other peaks are contaminants and can be ignored for this lab.
DATA COLLECTION AND CALCULATIONS
1. Calculate the number of moles of isopentyl alcohol:
(1.0 mL x 0.813 g/mL)/88.2 g/mole = 0.0092 mole
2 Calculate the number of moles of acetic acid:
(.550 mL x 1.06 g/mL)/60.1 g/mole = 0.0097 mole
3. What is the limiting reactant? isopentyl alcohol
4. Calculate the theoretical yield:
0.0092 moles x 130 g/mole = 1.196 g
REFERENCES
1. L. F. Fieser and K. L. Williamson, Organic Experiments, 6/e, D. C. Heath and Co., Lexington, MA, 1987.
2. D. L. Pavia, G. M. Lampman, G. S. Kriz, R. G. Engel, Introduction to Organic Laboratory Techniques, A Microscale Approach, Saunders College Publishing, San Francisco, CA 1990.
Assembly of the Reflux and Distilling Apparatus